Location

Stephen F Austin State University, Baker Pattillo Student Center, Student Center Theatre and Twilight Ballroom

Start Date

12-4-2022 4:00 PM

End Date

12-4-2022 7:00 PM

Description

A new method of determining the cation exchange capacity (CEC) of clay minerals was examined. This method involved exchanging the smectite clay with organic cations and using bomb calorimetry to measure the energy of combustion of the material. Because the clay is noncombustible, the energy is completely dependent on the amount of organic present, which is dependent on the CEC of the clay. Two organic cations, tetrapentylammonium and octadecyltrimethylammonium , with similar size but much different shape were used. For clays with lower CECs, using the more symmetric ion yielded better accuracy (4.24%), while for clays with higher CEC, using the straight chain organic yielded better accuracy (1.16%). Overall, the results indicate that using bomb calorimetry presents a viable option in the determination of cation exchange capacity.

Comments

Faculty Sponsor: Alyx Frantzen (Chemistry and Biochemistry)

Share

COinS

Tell us how this article helped you.

 
Apr 12th, 4:00 PM Apr 12th, 7:00 PM

Bomb Calorimetry: A New Method of CEC Determination

Stephen F Austin State University, Baker Pattillo Student Center, Student Center Theatre and Twilight Ballroom

A new method of determining the cation exchange capacity (CEC) of clay minerals was examined. This method involved exchanging the smectite clay with organic cations and using bomb calorimetry to measure the energy of combustion of the material. Because the clay is noncombustible, the energy is completely dependent on the amount of organic present, which is dependent on the CEC of the clay. Two organic cations, tetrapentylammonium and octadecyltrimethylammonium , with similar size but much different shape were used. For clays with lower CECs, using the more symmetric ion yielded better accuracy (4.24%), while for clays with higher CEC, using the straight chain organic yielded better accuracy (1.16%). Overall, the results indicate that using bomb calorimetry presents a viable option in the determination of cation exchange capacity.

 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.